beautypg.com

Comtech EF Data CDM-750 User Manual

Page 117

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–39

(CONFIG) IP Config: SNMP

ÆTraps

Traps: Community Version
IP-Addr#1 IP-Addr#2

()

 
Use the W X arrow keys to select CommunityVersionIP‐Addr#1, or IP‐Addr#2, and then press 
ENTER

(CONFIG) IP Config: SNMP

Æ Traps Æ Community

SNMP Traps Community:
Comtech (20 chars) (

v)

 
To  edit  the  SNMP  Traps  Community  string:  First,  use  the  W  X  arrow  keys  to select  the  alpha‐
numeric character to edit, and then use the ST  arrow keys to edit that character.  
 
Note  that  only  the  first  20  characters  on  the  bottom  line  are  available.  All  printable  ASCII 
characters  are  available  with  the  exception  of  the  backslash  ‘/’  (ASCII  code  92)  and  tilde  ‘~’ 
(ASCII code 126). 
 
Press  ENTER  once  you  compose  this  string.  All  trailing  spaces  are  removed  from  the  Traps 
Community string upon entry. 

(CONFIG) IP Config: SNMP

Æ Traps Æ Version

SNMP Traps Version:
SNMP-ver1 (ver1,ver2)

()

 
Use the 

◄ ►

arrow keys to select SNMP‐ver1 or SNMP‐ver2, and then press ENTER

(CONFIG) IP Config: SNMP

Æ Traps Æ IP-Addr#X

Trap IP addr #X:
000.000.000.000

(

v)

 
To  edit  the  SNMP  Trap  Destination  IP  Address  (where  X  designates  the  submenu  as  Trap  IP 
Address #1 or Trap IP Address #2): 
First, use the W X arrow keys to select a digit to edit, and 
then use the ST arrow keys to edit that digit. Press ENTER  when done. 

If both Trap IP Addresses are 000.000.000.000, it means Trap is disabled