CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–61

Selection 

Description

Alarm limits 

The  CDM‐750  constantly  monitors  the  LNB  power  supply  source. 
Use  this  selection  to  define  an  alarm  range  that  alerts  you  to 
problems with the LNB. You may define this range from a minimum 
of 000 mA to a maximum of 500 mA
 
To  establish  your  low  and  high  alarm  limit  values:  On  the  bottom 
line, first use the W X arrow keys to select a digit to edit, and then 
use  the  ST  arrow  keys  to  change  that  digit.  Press  ENTER  when 
done. 

 

5.2.8.1.2 (ODU) LNB:PwrSupply+Ref: PSUmonitor

LNB Power Supply [On]
274mA, 18.2V

 
The top line for this read‐only screen shows whether the LNB is On or Off
 

• If the LNB is On, the bottom line of this screen displays the present current and voltage 

readings for the LNB Power Supply. 
 

• If the LNB is Off, the bottom line reads 0000mA, 00.0V

 
Press ENTER or CLEAR to return to the previous menu.