CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Installation

MN-CDM750

2–2

 

This  equipment  contains  parts  and  assemblies  sensitive  to  damage  by  Electrostatic 
Discharge (ESD). Use ESD precautionary procedures when handling the equipment.
 

 

Once opened, inspect the shipment (Figure 2‐1): 

Step 

Task 

Keep all shipping materials for storage or reshipment. 

Check the packing list to ensure the shipment is complete. 

Inspect the equipment for any possible damage incurred during shipment. Contact 
the carrier and Comtech EF Data immediately to submit a damage report if damage is 
evident. 

 

Review this CDM‐750 Advanced High‐Speed Trunking Modem Installation 
and Operation Manual carefully to become familiar with operation. 

 

Proceed to Sect. 2.2 Installation into a Rack Enclosure. 

2.2

Installing into a Rack Enclosure

 

When mounting the CDM‐750 into a rack enclosure (Figure 2‐2): 

 

PROPER  GROUNDING  PROTECTION  IS  REQUIRED.  The  equipment  must  be 

connected to the protective earth connection at all times. It is therefore imperative 
that the unit is properly grounded, using the ground stud provided on the unit rear 
panel, during installation, configuration, and operation. 

 

PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high 

heat discharge, provide forced‐air cooling with top‐ or bottom‐mounted fans or 
blowers. 

 

o

Make sure there is adequate clearance inside the enclosure, especially at 
the side for air ventilation. 

 

o

Air  temperature  inside  the  rack  enclosure  should 

never

  exceed  50

°

(122

°

F). 

 

For  information  about  custom  rack  enclosures,  contact  Comtech  EF  Data 
Customer Support during normal business hours or visit Comtech EF Data’s Web 
site (www.comtechefdata.com/support.asp).