beautypg.com

3 snmp traps – Comtech EF Data CDM-750 User Manual

Page 148

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Ethernet-based Remote Product Management

MN-CDM750

6–4

6.3.3 SNMP Traps

The modem has the ability to send out SNMP traps when certain events occur in the modem. The 
modem sends out traps when an alarm or a fault occurs in the modem. These include unit faults, 
Tx faults, Rx faults, and ODU faults. A trap is sent both when a fault occurs and is cleared. 
 
The  modem  supports  both  SNMPv1  traps  and  SNMPv2  notifications.  Which  style  of  traps  the 
modem sends can be configured by the user using the CDM750SNMPTrapVersion OID: 
 

• The CDM‐750 supports the following MIB2 SNMPv1traps / SNMPv2 notifications: 

 

MIB2 SNMPv1 trap: Authentication Failure

5

MIB2 SNMPv2 notifications: Authentication Failure

1.3.6.1.6.3.1.1.5.5

 

• The CDM‐750 supports the following Alarms and Faults SNMPv1 traps: 

 

cdm750UnitAlarmV1

6247600

cdm750TxTrafficAlarmV1

6247601

cdm750RxTrafficAlarmV1

6247602

cdm750TrapStoredEventAlarm

6247603

cdm750RedundancySwitch

6247604

 

• The CDM‐750 supports the following Alarms and Faults SNMPv2 notifications:  

 

cdm750UnitAlarm

1.3.6.1.4.1.6247.55.2.1.1.1

cdm750TxTrafficAlarm

1.3.6.1.4.1.6247.55.2.1.1.2

cdm750RxTrafficAlarm

1.3.6.1.4.1.6247.55.2.1.1.3

cdm750TrapStoredEventAlarm

1.3.6.1.4.1.6247.55.2.1.1.4

cdm750RedundancySwitch

1.3.6.1.4.1.6247.55.2.1.1.5