Page 162

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Ethernet-based Remote Product Management

MN-CDM750

6–18

6.5.4.3.4 Configuration: LNB (Low Noise Block Down Converter)

 

This page is functional only when an optional LOW‐NOISE BLOCK DOWN CONVERTER 
is installed.
 

 
Use this page to configure Low‐Noise Block Down Converter parameters, and to view the LNB 
status for L‐Band operation. 
 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 6-8. Configuration | LNB page

LNB Control

The acceptable/valid operating range for each item in this section is provided in parentheses. 
 
LNB DC Power – Use the drop‐down list to select the power as OFF13V18V, or 24V
 
LNB Reference Enable – Use the drop‐down list to set LNB Reference operation as  ON or 

OFF

 
LNB Current Threshold (Low and High) (0‐500) – Enter a value (in mA) for either function. 
 
Set the desired LNB configurations. Click [Submit LNB Controls] to save these settings. 

LNB Status

This read‐only section provides the LNB Current (in mA) and LNB Voltage (in volts) information. 
The  report  updates  every  five  seconds.  This  interface  displays  both  values  as  0  when  no  LNB  is 
connected or is otherwise available for reporting.