beautypg.com

Comtech EF Data CDM-750 User Manual

Page 216

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Serial-based Remote Product Management

MN-CDM750

7–36

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

CnC Fractional

Time
Remaining

N/A

11 byte

Query only
Returns the fractional CnC time remaining in the current 365 day period in the form DD:HH:MM:SS, where:
DD=The number of days
HH=The number of hours
MM=The number of minutes
SS= The number of seconds

NOTE: This timer is only active when fractional CnC is purchased and CnC is enabled and running. When the timer hits
zero, CnC will be disabled until the current 365 day period expires. When the current 365 day period expiers, the
fractional timer will automatically reset to 90 days.

N/A

FCC?

FCC=DD:HH:MM:SS
(see Description of
Arguments)

Time remaining
in 365 day
period

N/A

12 bytes

Query only
Returns the time remaining in the current 365 day period, in the form DD:HH:MM:SS, where:
DD=The number of days
HH=The number of hours
MM=The number of minutes
SS=The number seconds

NOTE: When the timer hits zero, it will automatically reset to and begin counting down again.

N/A

FCF?

FCF=DD:HH:MM:SS
(see Description of
Arguments)

Demo Time

remaining

N/A

11 byte

Query only
Returns the Demo time remaining in the form DD:HH:MM:SS, where:
DD=The number of days
HH=The number of hours
MM=The number of minutes
SS=The number seconds

IMPORTANT NOTE! The Demo Mode timer cannot be reset. This timer is active only when Demo Mode is enabled.
When the timer hits zero, Demo Mode is permanently disabled.

N/A

DMT?

DMT=DD:HH:MM:SS
(see Description of