G.3.3 Status Items

Status items are not strictly part of the Statistics but are important items used for 
monitoring for current conditions.

G.3.4 BER Testing

Item

Comments

ModCod Selection

Allows selection of ModCod for test.

PN Sequence Test On/Off

Enable / Disable Test.

BER Test Result

Test results – continuous. PN data is generated in the Framer (Fig. B-1 Block 6) and recovered in
the Deframer (Fig. B-1 Block 5).

G.3.5 ACM Modulator Status

Item

Comments

Current TX ModCod

Currently active Tx ModCod.

Remote Es/No Reading

Es/No from distant end.

G.3.6 ACM Demodulator Status

Item

Comments

Rx ModCod

Currently active Rx ModCod.

Local Es/No Reading

Es/No of local demodulator.

G.3.7 CnC Status

Item

Comments

CnC PSD Ratio

Power Spectral Density (PSD) ratio at local end.
PSD = Interferer - Distant, density (dB).

CnC Ratio (Power)

Power Ratio at local end.
CnC Ratio = Interferer - Distant, power (dB).

CnC frequency offset

∆F between Interferer and Distant carriers.

CnC Delay

Round trip delay of Tx carrier in ms (measured in Fig. B-1 Block 8).