2 status | logs – Comtech EF Data CDM-750 User Manual
Page 164
CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Ethernet-based Remote Product Management
MN-CDM750
6–20
6.5.4.4.2 Status | Logs
Use this page to view logged faults and alarms, and to control how faults, alarms, and stored
statistics are processed by the unit. You may also to configure Alarm Masks for the unit with this
page.
Figure 6-10. Status | Logs page
Events Log
The scrollable window in this section provides a visual records of stored events. Up to 255
events may be displayed, sorted by order of occurrence in blocks of five. Note the following:
• Read Next Five Events – Select to buffer the next group of five stored events into the
scrollable Events window
• Clear Events Log – Select to purge the stored events log
• Initialize Events Pointer – Select to reset the log’s internal pointer
• Unread Events – Displays the total number of unread stored events in the Events
window. As stored event groups are displayed, this number decrements accordingly.
Click [Submit] to execute update of the scrollable window contents.
Alarm Mask
Set an available alarm as Alarm, Fault, or Mask (plus Fault (Tx On) for Decompression). Click
[Submit Settings] to execute update of the unit’s handling of faults and alarms.