3.3.3.2 DC Operation – Replacing Fuses

For  DC  operation  the  CDM‐750  requires  two  different  fuses  that  are  contained  within  the 
individual  screw‐in  receptacles  below  the  terminal  block  (located  on  the  rear  panel,  Figure 
3‐12
).
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-12. Replacing CDM-750 DC Fuses

 
To replace the fuses, follow these steps (Figure 3‐12
): 
 

 

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 

 

• First, unscrew either fuse holder from its receptacle. Then, remove and replace the modem 

and/or the BUC fuse(s): 

 

o

Use T3A (3 Amp) 250V fuses for modem operation (left‐hand receptable). 
 

o

Use T6.3A (6.3 Amp) 250V fuses when a Block Upconverter (BUC) is installed (right‐hand 
receptacle). 

 

 

FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH 
THE CORRECT TYPE AND RATING. 

 

• Screw either fuse holder back into its receptacle.