beautypg.com

7 (config) rx: esno – Comtech EF Data CDM-750 User Manual

Page 106

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–28

On the top line: The active Pilot setting displays here.  
 
On the bottom line: The user‐programmed Goldcode displays here. 
 
Press ENTER or CLEAR to return to the previous menu. 

5.2.2.3.7 (CONFIG) Rx: EsNo

Receive EsNo Alarm Point = 02.0 dB

(

v)

 
To edit the EsNo Alarm Point: First, use the W X arrow keys to select a digit to edit, and then use 
the ST arrows keys to change that digit. Note the following: 
 

• The permitted range is from 00.1 to 16.0 dB. 

 

• If the Rx Es/No falls below this value and the fault is NOT masked, a receive traffic fault 

will be generated. 

 
Press ENTER when done.