beautypg.com

2 test: bert, 1 test: bert ( config, 2 test: bert ( monitor – Comtech EF Data CDM-750 User Manual

Page 121: 1 test: bert æ config, 2 test: bert æ monitor

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–43

5.2.3.2 TEST: BERT

BERT: Config Monitor
(

34)

 
Use the W X arrow keys to select Config or Monitor, and then press ENTER

5.2.3.2.1 TEST: BERT

Æ Config

BERT Tx must selected as ON in order to monitor BERT testing, as this changes the 
format of the DVB frame sent and expected DVB frame received. 

 

BERT Tx:On
BERT Pattern: 2047 (

34v)

 
Use  the  W  X  arrow  keys  to  select  the  BERT  configuration  parameters,  and  then  use  the  ST 
arrow keys to edit that parameter setting. Note the following: 
 

Feature

Selection

BERT Tx

Off, On

BERT Pattern

2047, 2^15-1 (2

15

-1), 2^23-1 (2

23

-1)

5.2.3.2.2 TEST: BERT

Æ Monitor

BERT Tx must selected as ON in order to monitor BERT testing, as this changes the 
format of the DVB frame sent and expected DVB frame received. 

BER=NoSync Count=0.0E+00 Errs=0.0E+00
Restart Insert Error

 
Press ENTER to start the BERT Monitor. To clear all counts and re‐initiate testing, use the W X 
arrow keys to select Restart, and then press ENTER. 
 
If you previously selected BERT Tx: Off and you attempt to access this menu, the display appears 
as follows: 
 

BER= CTx BERT State is OFF!
Restart Press CLEAR to exit.

 
Press CLEAR as prompted to return to the TEST: BERT → Config menu to select BERT Tx: On