Appendix E. Es/No

MEASUREMENT

Although the CDM‐750 Advanced High‐Speed Trunking Modem calculates and displays the value 
of receive Es/No on the front panel of the unit, it is sometimes useful to measure the value using 
a spectrum analyzer, if one is available. 
 
The idea is to accurately measure the value of (Co+No)/No (Carrier density + Noise density/Noise 
density).  This  is  accomplished  by  tuning  the  center  frequency  of  the  Spectrum  analyzer  to  the 
signal of  interest, and  measuring  the  difference between the peak spectral  density of the  signal 
(the flat part of the spectrum shown) and the noise density. To make this measurement: 
 

Use a vertical scale of 1 or 2 dB/division. 
 

Set the Resolution Bandwidth of the Spectrum Analyzer to < 20% of the symbol rate. 

 

Use video filtering and/or video averaging to reduce the variance in the displayed trace 
to a low enough level that the difference can be measured to within 0.2dB.  

 

Place  a  marker  on  the  flat  part  of  the  signal  of  interest,  then  use  the  MARKER  DELTA 
function  to  put  a  second  marker  on  the  noise  to  the  side  of  the  carrier.  This  value  is 
(Co+No)/No, in dB. 

 

Use this value of (Co+No)/No in the table on the following page to determine the Eb/No. 
You will need to know the operating mode to read from the appropriate column. 

 

If  the  (Co+No)/No  value  measured  does  not  correspond  to  an  exact  table  entry, 
interpolate using the two nearest values. 

 
Note  that  the  accuracy  of  this  method  degrades  significantly  at  low  values  of  (Co+No)/No 
(approximately less than 6 dB).