beautypg.com

Comtech EF Data CDM-750 User Manual

Page 218

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Serial-based Remote Product Management

MN-CDM750

7–38

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Faults and

Status

N/A

9 bytes

Query only.

Returns the current highest-priority fault and status codes for the Unit (hardware), TX Traffic, RX Traffic, and ODUs in the
form aabccdexx, where:
aa = Unit status:

00=No faults
01=Main Board Power Supply 3.3V

02=Main Board Power Supply 1.5V
03=Main Board Power Supply 1.2V

04=Main Board Power Supply 1.8V
05=Main Board Power Supply 1.9V

06=Main Board Power Supply 2.5V
07=Main Board Power Supply 1.25V
08=Modem Board Power Supply 5.5V

09=Modem Board Power Supply 3.8V
10=Modem Board Power Supply 2.3V

11=Modem Board Power Supply 3.3V
12=Modem Board Power Supply 1.8V

13=Modem Board Power Supply 1.2V
14=Tx Power Cal

15=FPGA Load Fail
16=Reference Unlocked
17=Temperature Exceeded

18=General Fault
19=General Test Fault

20=PIIC1 External Clock Activity
21=PIIC1 External Clock In Range

22=PIIC2 External Clock Activity
23=PIIC2 External Clock In Range

NOTE: External clocks are not valid with OC3 interface
24 =General Test - Unit forced Good
b = Tx status:

0=No Faults
1=Input Data

2=PLL
3=General Test Fault

4=PIIC1 Symbol Clock PLL
5=PIIC2 Symbol Clock PLL

6=PIIC1 Input Signal Loss
7=PIIC2 Input Signal Loss
8 =General Test - Tx forced Good

cc = Rx status:
00=No Fault

01=Demodulator unlocked
02=AGC Signal Level

N/A

FLT?

FLT=aabccdexx

(see Description of
Arguments)