5.2.4 SELECT: Monitor

Monitor: Live-Alarms Stored-Events ACM
Rx-Params CnC Stats Buffer (

34)

 
Use the W X arrow keys to select Live‐AlarmsStored‐EventsACMRx‐ParamsCnC, or StatsP
and then press ENTER

5.2.4.1 Monitor: Live-Alarms

Live Unit=None
Alarms Rx=Demod Lock Tx=None

(

v)

 
An  example  of  an  Alarm  screen  is  shown  here.  Six  alarm  types  are  available  between  two 
screens. Note the arrows: Additional information is available by pressing the ST arrow keys: 
 

Live BUC=None
Alarms LNB=None

(

v)

 
The highest priority alarm currently active for each of the alarm types is as follows: 
 

Type

Alarm

State

Unit

MainPs X.X

Main Board Power Supply Fault

(3.3V, 1.5V, 1.2V, 1.8V, 1.9V, 2.5V, 1.25V)

MdmBdPs X.X

Modem Board Power Supply Fault

(5.5V, 3.8V, 2.3V, 3.3V, 1.8V, 1.2V)

Pwr Cal

Transmit power is not factory calibrated. Contact factory.

FPGA Load

An FPGA could not be configured.

Ref Unlock

Unit could not lock to external reference clock input.

Unit Temp

Unit has exceeded operating temperature.

Unit Fault

A general unit fault.

Tx
(Transmit)

Input Data

For enabled optional synchronous interfaces this alarm indicates a
problem with input data. Not applicable to Ethernet Interfaces.

Tx PLL

Transmit Phase-Lock Loop fault.

Rx
(Receive)

Demod Lock

Demodulator is not locked to a signal.

AGC Alarm

Receive Power Level has tripped AGC alarm point.

CnC Lock

Carrier-in-Carrier is enabled but not locked.

OutputData

For enabled optional synchronous interfaces this alarm indicates a
problem with output data. Not applicable to Ethernet Interfaces.

EsNo

Receive EsNo is below configured alarm point.

Rx PLL

Receive Phase-Lock Loop fault.