Comtech EF Data CDM-750 User Manual
Page 46

CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Installation
MN-CDM750
2–6
2.2.2
Installing the Optional Bearingless Rack Slide Set
The optional FP/SL0006 Bearingless Rack Slide Set may be installed into the equipment rack
enclosure and onto the sides of the CDM‐750 as shown in Figure 2‐4. Follow these steps to
install the rack slides:
Step
Task
1
Use the provided mounting hardware to install one slide onto each side of the CDM-750
chassis.
2
Use the provided mounting hardware to install the slide rail components into each interior
side of the rack enclosure.
3
Mount the unit into the front of the rack enclosure. Ensure that the slides properly engage
the enclosure-mounted slide rails.
4
Continue to slide the modem into the enclosure to its final operating position. Then, use
four user-provided screws to secure the modem to the enclosure’s right and left threaded
front mounting rails (through the modem front panel mounting slots).
CEFD Part Number
Description
FP/SL0006
Bearingless Rack Slide Set – 26”
Figure 2-4. Installing the Optional Bearingless Rack Slide Set