Page 147

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Ethernet-based Remote Product Management

MN-CDM750

6–3

6.3.1 Management Information Base (MIB) Files

MIB  files  are  used  for  SNMP  remote  management  of  a  unique  device.  A  MIB  file  consists  of  a 
tree  of  nodes  called  Object  Identifiers  (OIDs).  Each  OID  provides  remote  management  of  a 
particular function. These MIB files should be compiled in a user‐supplied MIB Browser or SNMP 
Network Monitoring System server. The following MIB files are associated with the CDM‐750: 

 

MIB File/Name
(where ‘x’ is revision letter)

Description

FW10874-2-.mib
ComtechEFData Root MIB file

ComtechEFData MIB file gives the root tree for ALL Comtech EF Data
products and consists of only the following OID:

Name: comtechEFData
Type: MODULE-IDENTITY

OID: 1.3.6.1.4.1.6247

Full

path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFDa

ta(6247)
Module: ComtechEFData

FW-0000083L .mib
CDM-750 MIB file

MIB file consists of all of the OIDs for management of the modem functions

FW-0000084- .mib
CDM-750 Traps MIB file

Trap MIB file is provided for SNMPv1 traps common for modem.

6.3.2 SNMP Community Strings

 

In    SNMP  v1/v2c,  the  SNMP  Community  String  is  sent  unencrypted  in  the  SNMP 
packets. Caution must be taken by the network administrator to ensure that SNMP 
packets travel only over a secure and private network if security is a concern.  

The  CDM‐750  uses  Community  Strings  as  a  password  scheme  used  to  authenticate  users  and 
determine access privileges to the SNMP Agent MIBs. Type the SNMP Community String into the 
user‐supplied MIB Browser or Network Node Management software. 
 
Three Community Strings are defined for SNMP access:  
 

• Read Community 

default = public 

 

• Write Community  

default = private 

 

• Traps Community 

default = comtech 

 

  For  proper  SNMP  operation,  the  CDM‐750  MIB  files  must  be  used  with  the 

associated version of the CDM‐750 modem M&C. Refer to the CDM‐750 FW Release 
Notes for information on the required FW/SW compatibility.