CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–27

5.2.2.3.4 (CONFIG) Rx: Mod (Modulation)

Modcod=QPSK 1/2 Read Only

 
This read‐only screen identifies the active modulation type. Press ENTER or CLEAR to return to 
the previous menu. 

5.2.2.3.5 (CONFIG) Rx: Data

Rx Data Rate Rx Symbol Rate

()

 
Use the W X arrows keys to select Rx Data Rate or Rx Symbol Rate, and then press ENTER

(CONFIG) Rx: Data

Æ Rx Data Rate

Rx Data Rate = 070000.000 kbps

(

v)

 
This  read‐only  screen  identifies  the  active  Rx  Data  Rate.  To  properly  lock  an  Rx  path  and 
automatically obtain the Rx Data Rate, you need to make changes as necessary to the Rx Symbol 
Rate, Gold‐n Index Code (Goldcode), and Rx IF Frequency of the modem. Press ENTER or CLEAR to 
return to the previous menu. 

(CONFIG) Rx: Data

Æ Rx Symbol Rate

Rx Symbol Rate = 30000.000 ksps

(

v)

 
To change the Symbol Rate: First, use the W X arrow keys to select a digit to edit, and then use 
the ST arrow keys to change that digit. Press ENTER when done. 
 
Once  the  Rx  path  is  synchronized,  the  correct  data  rate,  modulation  type,  code  rate,  pilots 
ON/OFF, FEC frame length spectral inversion, etc. appear in the appropriate Rx menus. 

5.2.2.3.6 (CONFIG) Rx: Pilot

In  order  to  properly  lock  to  a  carrier,  it  is  critical  that  the  Rx  Goldcode  value 
matches the Tx Goldcode value of the distant end modem. 

 

Rx: Pilot=Off Read Only
Goldcode=000000

(

v)