CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–15

(CONFIG: INTF) PIICX (OC3)

Æ ClkSourceÆ RxClock

Rx Clock Source: RX CLK
(
)

 
To  set  the  clock  source  by  which  Rx  data  is  clocked  out  of  the  OC3/STM‐1  interface  to  the 
external baseband equipment:
 Use the ST arrow keys to select RX SATINT CLK, or TX CLK, and 
then press ENTER.  

(CONFIG: INTF) PIICX (OC3)

Æ RxBuffer

Rx Buffer: BufferSize ReCenter
Fill Status = 00% (
)

 
Use the W X arrow keys to select BufferSize or ReCenter, and then press ENTER
 
The bottom line displays the present RxBuffer Fill Status as a percentage. If the RxBuffer Fill Status 
is dropping (approaching 0%), this indicates that the Rx traffic is not keeping up with the Rx Clock 
setting  and  a  data  underflow  is  occurring.  If  the  RxBuffer  Fill  Status  is  increasing  (approaching 
100%)  the  Rx  traffic  is  coming  in  faster  than  the  Rx  Clock  setting  accommodates,  and  a  data 
overflow 
is occurring. 

(CONFIG: INTF) PIICX (OC3)

Æ RxBuffer Æ BufferSize

Rx Buffer Size: 02.0 ms
(
)

 
Use the ST arrow keys to increment/decrement the Rx Buffer Size time value (from 2 ms to 75 
ms in 0.5 ms steps), and then press ENTER

(CONFIG: INTF) PIICX (OC3)

Æ RxBuffer Æ Recenter

Rx Buffer: ReCenter
(
)

 
In the event of data underflow or overflow (as indicated by the Fill Status percentage reported 
on the RxBuffer menu) press ENTER to ReCenter the Rx Buffer depth to 50%. 

(CONFIG: INTF) PIICX (OC3)

Æ Mask

Masks: TxPll InpSigLoss
RxPll RxOF RxUF

 
To define how many or how few of the interface alarm or fault states are reported: Use the W X 
arrow  keys  to  select  TxPll,  InpSigLoss,  RxPllRxOF,  or  RxUF,  and  then  press  ENTER.  Note  the 
following: