CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–22

5.2.2.2.5 (CONFIG) Tx: Mod (Modulation)

Modcod=QPSK 1/2 (

v)

 
Use the ST arrow keys to select the modulation and FEC type, and then press ENTER. Note the 
following: 
 

• Use the ModCod setting “Auto (ACM)” when running in ACM mode. In ACM mode, you do 

not  directly  control  the  ModCod  used  at  any  given  moment,  but  rather  the  ModCod 
chosen for the Tx carrier is based on the rules and configuration of the ACM parameters. 
See Sect. 5.2.2.5 CONFIG: ACM for configuration of ACM parameters. 
 

• The upper range of modulation and coding as well as Auto (ACM) capability is dictated by 

the FAST option(s) installed. 

5.2.2.2.6 (CONFIG) Tx: Data

Tx Data Rate Tx Symbol Rate

()

 
Use the W X arrow keys to select Tx Data Rate or Tx Symbol Rate, and then press ENTER

(CONFIG) Tx: Data

Æ Tx Data Rate

To configure the Tx Data Rate of the modem, the modem must be in Single Stream 
Mode with only the Ethernet interfaces active. You can tell when the modem is in 
Single Stream Mode / Ethernet only when the minimum data rate (MIN_DR) is zero 
(000000.000) and the Read Only (RO) indication does not appear at the upper right‐
hand of the menu. 
 
If  the  screen  displays  any  minimum  data  rate  other  than  zero,  this  indicates  that 
the  modem  is  in  MultiStream  Mode  –  the  data  rate  cannot  be  changed  while  in 
MultiStream  Mode.  See
  Sect.5.2.2.1.1  Single  Stream  Mode  vs.  MultiStream  Mode 
Operation for instructions on entering into or exiting out of MultiStream Mode. 
 

ETH_DR + MIN_DR = TOT_DR (RO)

019484.479__034883.520__054367.999Kbps

 
Referring  to  the  example  shown  here:  Per  the 

ETH_DR + MIN_DR = TOT_DR(RO)

  equation 

provided on the top line, note the following: 
 

Operand 

Means 

Description 

ETH_DR

Ethernet Data Rate This is all data associated with the Ethernet data interfaces. It is always

TOT_DR – MIN_DR