beautypg.com

Comtech EF Data CDM-750 User Manual

Page 200

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Serial-based Remote Product Management

MN-CDM750

7–20

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Unit Alarm

Mask

MSK=

36 bytes

Command or Query.

Set or return unit alarm masks in the form abcdefgxxxxxxxxxhijklmxxxxnopqrsxxxx, where:

Unit Alarm mask conditions, in form abcdefg, where:

a = Rx AGC Alarm***

b = Es/No Alarm***

c =

d = LNB

e = Reference alarm

f = Reserved

g = Rx decompression mismatch alarm***

xxxxxxxxx (9 spares)

PIIC1 Alarm mask conditions, in form hijklm, where:

h = Rx Buf PLL Alarm***

i = Rx Buf OverFlow Alarm***

j = rx Buf UnderFlow Alarm***

k = Ext Clk Act Alarm

l = Ext Clk In Range Alarm

m = input signal loss Alarm

n = Tx Symbol Clock PLL Alarm

xxx (3 spares)

PIIC2 Alarm mask conditions, in form nopqrs, where:

n = Rx Buf PLL Alarm***

o = Rx Buf OverFlow Alarm***

p = rx Buf UnderFlow Alarm***

q = Ext Clk Act Alarm

r = Ext Clk In Range Alarm

s = input signal loss Alarm

t = Tx Symbol Clock PLL Alarm

xxx (3 spares)

For PIIC1 And PIIC2

U = Uninstalled

X = Installed/Spare

Value of each mask:

*** indicates a 3 state mask where

0 = Unmasked Alarm (will not cause a redundant switch)

1 = Unmasked Fault (default, causes redundant switch)

2 = Masked (Ignore alarm or fault)

All other masks are 4 state masks where

0 = Unmasked Alarm (will not cause a redundant switch)

1 = Unmasked Fault (default, causes redundant switch)

2 = Masked (Ignore alarm or fault)

3 = Unmasked Fault Tx On (causes redundant switch but leaves Transmit output power on)

NOTE: Masks for alarms that are not applicable to various interface types (such as external clocks for OC3) are reserved as placeholders

and will not have any affect on operation.

Example: MSK=110010100000000000000000000000000000

MSK=

MSK?
MSK*

MSK#

MSK?

MSK=

abcdefgxxxxxxxxx
hijklmxxxx
nopqrsxxxx


(see Description of

Arguments)