beautypg.com

Hard ip status extension – Altera Stratix V Avalon-MM Interface for PCIe Solutions User Manual

Page 50

background image

Hard IP Status Extension

Table 4-10: Hard IP Status Extension Signals

This optional bus adds signals that are useful for debugging to the top-level variant, including:
• The most important native Avalon-ST RX signals

• The Configuration Space signals

• The BAR

• The ECC error

• The signal indicating that the

pld_clk

is in use

Signal

Direction

Description

pld_clk_inuse

Output

When asserted, indicates that the Hard IP Transaction Layer is

using the

pld_clk

as its clock and is ready for operation with the

Application Layer. For reliable operation, hold the Application

Layer in reset until

pld_clk_inuse

is asserted.

pme_to_sr

Output

Power management turn off status register.
Root Port—This signal is asserted for 1 clock cycle when the Root

Port receives the

pme_turn_off

acknowledge message.

Endpoint—This signal is asserted for 1 cycle when the Endpoint

receives the

PME_turn_off

message from the Root Port.

UG-01097_avmm

2014.12.15

Hard IP Status Extension

4-17

64- or 128-Bit Avalon-MM Interface to the Application Layer

Altera Corporation

Send Feedback

This manual is related to the following products: