Nor-Cal SDC15 Controller User Manual
Page 191
Bank
Item name
RAM address
EEPROM address
RAM
EEPROM
Decimal point
Remarks
Decimal Hexadecimal Decimal Hexadecimal Read Write Read Write information
DO
Control output 2 Polarity
5621
15F5
22005
55F5
—
Assignment
Control output 2 Latch
5622
15F6
22006
55F6
—
Event output 1 Operation type
5623
15F7
22007
55F7
—
Event output 1 Output assign A
5624
15F8
22008
55F8
—
Event output 1 Output assign B
5625
15F9
22009
55F9
—
Event output 1 Output assign C
5626
15FA
22010
55FA
—
Event output 1 Output assign D
5627
15FB
22011
55FB
—
Event output 1 Polarity A
5628
15FC
22012
55FC
—
Event output 1 Polarity B
5629
15FD
22013
55FD
—
Event output 1 Polarity C
5630
15FE
22014
55FE
—
Event output 1 Polarity D
5631
15FF
22015
55FF
—
Event output 1 Polarity
5632
1600
22016
5600
—
Event output 1 Latch
5633
1601
22017
5601
—
Event output 2 Operation type
5634
1602
22018
5602
—
Event output 2 Output assign A
5635
1603
22019
5603
—
Event output 2 Output assign B
5636
1604
22020
5604
—
Event output 2 Output assign C
5637
1605
22021
5605
—
Event output 2 Output assign D
5638
1606
22022
5606
—
Event output 2 Polarity A
5639
1607
22023
5607
—
Event output 2 Polarity B
5640
1608
22024
5608
—
Event output 2 Polarity C
5641
1609
22025
5609
—
Event output 2 Polarity D
5642
160A
22026
560A
—
Event output 2 Polarity
5643
160B
22027
560B
—
Event output 2 Latch
5644
160C
22028
560C
—
Event output 3 Operation type
5645
160D
22029
560D
—
Event output 3 Output assign A
5646
160E
22030
560E
—
Event output 3 Output assign B
5647
160F
22031
560F
—
Event output 3 Output assign C
5648
1610
22032
5610
—
Event output 3 Output assign D
5649
1611
22033
5611
—
Event output 3 Polarity A
5650
1612
22034
5612
—
Event output 3 Polarity B
5651
1613
22035
5613
—
Event output 3 Polarity C
5652
1614
22036
5614
—
Event output 3 Polarity D
5653
1615
22037
5615
—
Event output 3 Polarity
5654
1616
22038
5616
—
Event output 3 Latch
5655
1617
22039
5617
—
Event
Internal Event 1 Operation type
5801
16A9
22185
56A9
—
Configuration Internal Event 1 Direct/Reverse
5802
16AA
22186
56AA
—
Internal Event 1 Standby
5803
16AB
22187
56AB
—
Internal Event 1 state at READY
5804
16AC
22188
56AC
—
(Reserved for future extension.)
5805
16AD
22189
56AD
∆
∆
∆
∆
—
Internal Event 1 Controller alarm OR
5806
16AE
22190
56AE
—
Internal Event 1 Special OFF setup
5807
16AF
22191
56AF
—
Internal Event 1 Delay unit
5808
16B0
22192
56B0
—
(Reserved for future extension.)
5809
16B1
22193
56B1
∆
∆
∆
∆
—
Internal Event 2 Operation type
5810
16B2
22194
56B2
—
Internal Event 2 Direct/Reverse
5811
16B3
22195
56B3
—
Internal Event 2 Standby
5812
16B4
22196
56B4
—
Internal Event 2 state at READY
5813
16B5
22197
56B5
—
(Reserved for future extension.)
5814
16B6
22198
56B6
∆
∆
∆
∆
—
Internal Event 2 Controller alarm OR
5815
16B7
22199
56B7
—
9-5
Chapter 9. LIST OF COMMUNICATION DATA