Nor-Cal SDC15 Controller User Manual
Page 189
9-3
Chapter 9. LIST OF COMMUNICATION DATA
Bank
Item name
RAM address
EEPROM address
RAM
EEPROM
Decimal point
Remarks
Decimal Hexadecimal Decimal Hexadecimal Read Write Read Write information
Setup
(Reserved for future extension.)
5254
1486
21638
5486
∆
X
∆
X
S
(Reserved for future extension.)
5255
1487
21639
5487
∆
X
∆
X
S
(Reserved for future extension.)
5256
1488
21640
5488
∆
X
∆
X
—
(Reserved for future extension.)
5257
1489
21641
5489
∆
X
∆
X
—
(Reserved for future extension.)
5258
148A
21642
548A
∆
X
∆
X
1
(Reserved for future extension.)
5259
148B
21643
548B
∆
X
∆
X
—
(Reserved for future extension.)
5260
148C
21644
548C
∆
X
∆
X
—
(Reserved for future extension.)
5261
148D
21645
548D
∆
X
∆
X
—
(Reserved for future extension.)
5262
148E
21646
548E
∆
X
∆
X
—
(Reserved for future extension.)
5263
148F
21647
548F
∆
X
∆
X
1
CPL/MODBUS
5264
1490
21648
5490
X
X
—
Station address
5265
1491
21649
5491
X
X
—
Transmission speed
5266
1492
21650
5492
X
X
—
Data format (Data length)
5267
1493
21651
5493
X
X
—
Data format (Parity)
5268
1494
21652
5494
X
X
—
Data format (Stop bit)
5269
1495
21653
5495
X
X
—
Response time-out
5270
1496
21654
5496
X
X
—
Key operation type
5271
1497
21655
5497
—
[mode] key function
5272
1498
21656
5498
—
MODE display setup
5273
1499
21657
5499
—
PV/SP display setup
5274
149A
21658
549A
—
MV display setup
5275
149B
21659
549B
—
EV display setup
5276
149C
21660
549C
—
Timer remain time display setup
5277
149D
21661
549D
—
CT display setup
5278
149E
21662
549E
—
User level
5279
149F
21663
549F
—
Communication monitor display
5280
14A0
21664
54A0
—
(Reserved for future extension.)
5281
14A1
21665
54A1
∆
∆
∆
∆
—
(Reserved for future extension.)
5282
14A2
21666
54A2
∆
∆
∆
∆
—
(Reserved for future extension.)
5283
14A3
21667
54A3
∆
∆
∆
∆
—
(Reserved for future extension.)
5284
14A4
21668
54A4
∆
∆
∆
∆
—
(Reserved for future extension.)
5285
14A5
21669
54A5
∆
∆
∆
∆
—
(Reserved for future extension.)
5286
14A6
21670
54A6
∆
∆
∆
∆
—
(Reserved for future extension.)
5287
14A7
21671
54A7
∆
∆
∆
∆
—
(Reserved for future extension.)
5288
14A8
21672
54A8
∆
∆
∆
X
—
(Reserved for future extension.)
5289
14A9
21673
54A9
∆
X
∆
X
—
CT1 turns
5290
14AA
21674
54AA
—
(Note 1)
Number of CT1 power wire loops
5291
14AB
21675
54AB
—
(Note 1)
CT2 turns
5292
14AC
21676
54AC
—
(Note 1)
Number of CT2 power wire loops
5293
14AD
21677
54AD
—
(Note 1)
DI
Internal Contact 1 Operation type
5401
1519
21785
5519
—
Assignment
Internal Contact 1 Input bit function
5402
151A
21786
551A
—
Internal Contact 1 Input assign A
5403
151B
21787
551B
—
Internal Contact 1 Input assign B
5404
151C
21788
551C
—
Internal Contact 1 Input assign C
5405
151D
21789
551D
—
Internal Contact 1 Input assign D
5406
151E
21790
551E
—
(Note 1) If ROM version 1 of the instrument information bank (Id02) is prior to 2.04, the item name is “reserved
for future extension,” the symbol in the read column is ∆, and the symbol in the write column is x for
both RAM and EEPROM.