Nor-Cal SDC15 Controller User Manual
Page 188
Bank
Item name
RAM address
EEPROM address
RAM
EEPROM
Decimal point
Remarks
Decimal Hexadecimal Decimal Hexadecimal Read Write Read Write information
Setup
PV input range low limit
5205
1455
21589
5455
✽
✽
P
PV input range high limit
5206
1456
21590
5456
✽
✽
P
SP low limit
5207
1457
21591
5457
P
SP high limit
5208
1458
21592
5458
P
PV square root extraction dropout
5209
1459
21593
5459
✽
✽
1
(Reserved for future extension.)
5210
145A
21594
545A
∆
X
∆
X
—
(Reserved for future extension.)
5211
145B
21595
545B
∆
X
∆
X
P
(Reserved for future extension.)
5212
145C
21596
545C
∆
X
∆
X
P
(Reserved for future extension.)
5213
145D
21597
545D
∆
X
∆
X
—
Control action (Direct/Reverse)
5214
145E
21598
545E
—
Output operation at PV alarm
5215
145F
21599
545F
—
Output at PV alarm
5216
1460
21600
5460
1
Output at READY (Heat)
5217
1461
21601
5461
1
Output at READY (Cool)
5218
1462
21602
5462
1
Output operation at changing
5219
1463
21603
5463
—
Auto/Manual
Preset MANUAL value
5220
1464
21604
5464
1
Initial output type (mode) of PID control
5221
1465
21605
5465
—
Initial output of PID control
5222
1466
21606
5466
1
(Reserved for future extension.)
5223
1467
21607
5467
∆
X
∆
X
—
(Reserved for future extension.)
5224
1468
21608
5468
∆
X
∆
X
—
(Reserved for future extension.)
5225
1469
21609
5469
∆
X
∆
X
—
Heat/Cool control
5226
146A
21610
546A
—
Heat/Cool selection
5227
146B
21611
546B
—
Heat/Cool control dead zone
5228
146C
21612
546C
1
Heat/Cool control change point
5229
146D
21613
546D
1
LSP system group
5230
146E
21614
546E
—
(Reserved for future extension.)
5231
146F
21615
546F
∆
X
∆
X
—
SP ramp unit
5232
1470
21616
5470
—
(Reserved for future extension.)
5233
1471
21617
5471
∆
X
∆
X
—
(Reserved for future extension.)
5234
1472
21618
5472
∆
X
∆
X
—
(Reserved for future extension.)
5235
1473
21619
5473
∆
X
∆
X
—
CT1 operation type
5236
1474
21620
5474
—
CT1 output
5237
1475
21621
5475
—
CT1 measurement wait time
5238
1476
21622
5476
—
CT2 operation type
5239
1477
21623
5477
—
CT2 output
5240
1478
21624
5478
—
CT2 measurement wait time
5241
1479
21625
5479
—
Control output 1 range
5242
147A
21626
547A
—
Control output 1 type
5243
147B
21627
547B
—
Control output 1 scaling low limit
5244
147C
21628
547C
S
Control output 1 scaling high limit
5245
147D
21629
547D
S
Control output 1 MV scaling
5246
147E
21630
547E
P
(Note 1)
Control output 2 range
5247
147F
21631
547F
—
Control output 2 type
5248
1480
21632
5480
—
Control output 2 scaling low limit
5249
1481
21633
5481
S
Control output 2 scaling high limit
5250
1482
21634
5482
S
Control output 2 MV scaling
5251
1483
21635
5483
P
(Note 1)
(Reserved for future extension.)
5252
1484
21636
5484
∆
X
∆
X
—
(Reserved for future extension.)
5253
1485
21637
5485
∆
X
∆
X
—
9-2
Chapter 9. LIST OF COMMUNICATION DATA