Test Setup - Test Configurator, Timer, and System

Packet Blazer

87

FTFL/PT

FTFL/PT

From the Test menu, tap Setup, Test Configurator, tap on the signal block,
and on the FTFL/PT tab.

ODUx Buttons

Tap on an ODUx button to select the multiplexed level.

FTFL

Allows the configuration of the Forward and Backward ODU Fault Type
Fault Location (FTFL) to be generated.

Fault Indication and Fault Indication Code allow the selection of the
FTFL fault indicator message/code (byte 0 for forward, byte 128 for
backward) to be generated.

Note: The Fault Indication Code field is automatically updated when the Fault

Indication is changed and vice versa.

Operator Identifier allows editing the Operator Identifier to be
generated (bytes 1 to 9 for forward, bytes 129 to 137 for backward;
9 characters allowed). By default no Operator Identifier is defined.

Operator Specific allows editing the Operator Specific to be
generated (bytes 10 to 127 for forward, bytes 138 to 255 for backward;
118 characters allowed). By default no Operator Specific is defined.

Fault Indication

Fault Indication Code (Hex)

No fault

00 (default)

Signal fail

01

Signal Degrade

02

Reserved

03

a

a.

Selecting Reserved will use the hexadecimal code 03 but, all codes from 03 to FF

are reserved for future international standardization.