beautypg.com

Rx mismatch – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual

Page 219

background image

Test Results

Packet Blazer

209

GFP-F/GFP-T

Reserved PTI indicates the received client data and management
frames with a payload type identifier different of 000 and 100 without
uncorrectable cHEC, tHEC, and eHEC, and pFCS errors. Possible rate
units are Frames (default), or Bytes per second.

Reserved PLI indicates the number of reserved control frames (PLI=1,
2, or 3 while in Synchronization state) received.

Invalid indicates the number of received frames corresponding to at
least one of the following conditions:

EXI=0000 while PFI=1 and PLI <8

EXI=0001 while PFI=0 and PLI <8

EXI=0001 while PFI=1 and PLI<12

Discarded indicates the number of received frames with
uncorrectable tHEC, eHEC errors, or Invalid Frames.

Total indicates the received frames including Idle, Client Data, Client
Management, and frames with a reserved PTI. Possible rate units are
Frames (default), or Bytes per second.

RX Mismatch

PFI (Payload Frame Check Sequence Identifier) indicates the number
of frames with PFI field not matching the expected PFI.

EXI (Extension Header Identifier) indicates the number of frames with
EXI field not matching the expected EXI.

UPI (User Payload Identifier) indicates the number of frames UPI field
not matching the expected UPI.

CID (Channel IDentifier), only available when EXI is et to Linear,
indicates the number of frames CID field not matching the expected
CID.

Note: For expected values, refer to GFP-F/GFP-T on page 90 for more information.