EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 72
Test Setup - Test Configurator, Timer, and System
62
FTB/IQS-85100G
BERT and Unframed BERT
TX Pattern/RX Pattern sets respectively the TX and RX test pattern.
The pattern is set for all lanes for parallel interface.
When User Pattern is selected, enter the payload pattern hexadecimal
value.
Invert check box, when selected (cleared by default), inverts the test
pattern meaning that every 0 will be changed for 1 and every 1 for 0.
For example, the pattern 1100 will be sent as 0011.
All Lanes check box is available with an unframed test with parallel
interface. When selected, it allows to set the same TX and/or RX test
pattern for all lanes. When All Lanes check box is cleared (default), a
different test pattern may be set for each lane.
When the All Lanes check box is cleared, for an unframed test, the
following pattern settings are available for each lane.
TX Pattern/RX Pattern: Select the test pattern from the list for each
lane and direction (TX and RX). Choices are PRBS9, PRBS11, PRBS15,
PRBS20, PRBS23, and PRBS31 (default).
Test
OTN BERT - framed
PRBS9, PRBS15, PRBS20, PRBS23, PRBS31 (default),
Null Client, and User Pattern.
OTN BERT - unframed
PRBS9, PRBS11, PRBS15, PRBS20, PRBS23,
PRBS31 (default), Square Wave 1 zero/one,
Square Wave 2 zeros/ones,
Square Wave 4 zeros/ones,
Square Wave 8 zeros/ones, and
Square Wave 16 zeros/ones
a
.
a.
Square Wave patterns are only available when the All Lanes check box is selected.
Not available with 20 Unframed Physical Lanes.
OTN-SONET/SDH BERT,
SONET/SDH BERT
PRBS9, PRBS11, PRBS15, PRBS20, PRBS23, PRBS31,
1111, 1100, 1010, 0000, 1in8, 1in16, 2in8, and
User Pattern.