Etherbert and unframed bert, Link, Restore < test application > defaults – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 82: Pattern
Test Setup - Test Configurator, Timer, and System
72
FTB/IQS-85100G
EtherBERT and Unframed BERT
EtherBERT and Unframed BERT
From the Test menu, tap Setup, Test Configurator, and tap on the
EtherBERT or Unframed BERT block.
LINK
Note: Available with OTN BERT test application with Ethernet client (EoOTN).
A green/red arrow is used to indicate the status of the link at the PCS level:
A green arrow indicates that the link is up.
A red arrow indicates alarms at the PCS level, the link is down.
The Local Fault Detected, Local Fault Received, Remote Fault,
LOA (OTU4), Hi-BER (OTU4), LOBL1027B (OTU3), Hi-BER1027B (OTU3),
and LOAML1027B (OTU3) alarms are displayed. Refer to Ethernet on
page 173, Ethernet - PCS Lanes on page 175, and Transcoding on page 203
for more information.
Restore < Test Application > Defaults
Note: Available with OTN BERT test application with Ethernet client (EoOTN).
Reverts the current test application to its default factory settings.
Pattern
Coupled RX to TX check box, when selected (default), couples both
the TX and RX signal with the same test pattern.
RX Pattern Analysis check box, when selected (default), monitors the
received traffic pattern and Round-Trip Latency. See BER on page 171
for more information.