beautypg.com

Odux-tcm – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual

Page 198

background image

Test Results

188

FTB/IQS-85100G

Alarms/Errors

ODUx-TCM

Alarms

BDI (Backward Defect Indication)

RX: The BDI bit in the TCM overhead field Byte 3, bit 5 is “1” for at least
5 consecutive frames.

TX: Generates a "1" in the BDI bit of the TCM overhead field (byte 3,
bit 5) continuously.

BIAE (Backward Incoming Alignment Error)

RX: The BEI/BIAE bits in the TCM overhead field Byte 3, bits 1 to 4 are
“1011” for at least 3 consecutive frames.

TX: Generates "1011" in the BEI/BIAE bits of the TCM overhead (byte 3,
bits 1 to 4) continuously.

IAE (Incoming Alignment Error)

RX: The STAT information in the TCM is “010” for at least 3 consecutive
frames.

TX: Generates "1" in the IAE bit of the TCM overhead (byte 3, bit 6)
continuously.

LTC (Loss of Tandem Connection)

RX: The STAT information in the TCM Byte 3, bits 6, 7, and 8 are “000”
for at least 3 consecutive frames.

TX: Generates "000" in the STAT field of TCM overhead (byte 3, bits
6 to 8) continuously.

TIM (Trace Identification Mismatch)

RX: The SAPI and/or DAPI do not math the expected SAPI and/or DAPI.
This alarm is only available when the Enable TIM SAPI and/or DAPI
check boxes are selected from PT on page 88.