Test Results

Packet Blazer

235

Summary (EtherSAM)

Test/Power Recovery: Test Recovery (Widows 8 or above) or
Power Recovery (Windows XP), when displayed, indicates that the
test has automatically recovered from a power failure. The number of
occurrences is also displayed next to the Test/Power Recovery field.
Refer to Power Failure Recovery on page 329.

Logger Full, when displayed, indicates that the logger is full. Refer to
Logger on page 213.

Service Configuration/Performance Test: Tap Service Configuration
Test
or Service Performance Test button to view the result summary
of the corresponding test.

Service indicates the service’s number and name. For Service
Configuration Test
, the number/name is highlighted in red per
service when VLAN mismatch occurred; in Dual Test Set, the
direction is also highlighted; in Dual Test Set, the R -> L direction
label is gray when VLAN Preservation is not supported by the
remote module.

Direction, available with Dual Test Set, indicates results from local
to remote (L -> R) and remote to local (R -> L).

Service Performance Test column displays the pass/fail verdict
icon indicating if the service complies to the configured SLA
parameters.

Service Configuration Test column displays the pass/fail verdict
icon indicating if the service complies to the configured SLA
parameters.