Traces (sonet/sdh), Traces – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 172
Test Setup - Test Configurator, Timer, and System
162
FTB/IQS-85100G
Traces (SONET/SDH)
Traces (SONET/SDH)
For SONET/SDH BERT, from the Test menu, tap Setup, Test Configurator,
the interface block, and on the Traces tab.
For OTN-SONET/SDH BERT, from the Test menu, tap Setup, Test
Configurator, the protocol block, and on the Traces tab.
Note: Selecting a Trace byte to be generated will automatically update the
corresponding OH byte. Refer to OH - SONET/SDH on page 291 for more
information.
Traces
Section/RS (J0), and STS/AU/TU-3 Path (J1)
Format: Allows the selections of the J0/J1 format: 1 Byte (default), 16
Bytes, or 64 Bytes format.
Generated: When the 16 bytes or 64 bytes format is selected, enter the
J0/J1 trace value/message to be generated.
Default values/messages
Format
(bytes)
Traces
J0/J1
1
01
a
a.
Hexadecimal value. Refer to OH - SONET/SDH on page 291 to change this value.
J0/J1
16
EXFO SONET/SDH
J0/J1
64
EXFO SONET/SDH Analyzer Section/RS trace test message
J0
EXFO SONET/SDH Analyzer high order path trace test message
J1 (STS/AU)
EXFO SONET/SDH Analyzer low order path trace test message J1
(TU-3)