Tcm access point identifier – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 173
Test Setup - Test Configurator, Timer, and System
Packet Blazer
163
Traces (SONET/SDH)
Note: 16-bytes selection allows typing up to 15 bytes (a CRC-7 byte will be added
in front for a total of 16 bytes). 64-bytes selection allows typing up to
62-bytes (
R
> and
F
> bytes will be added at the end for a total of
64-bytes). Traces values should be ASCII suitable characters including the
ITU T.50 Characters on page 24.
TIM-S/RS-TIM, TIM-P/HP-TIM: Enables the corresponding Trace
Identifier Mismatch for the expected message defined. These settings
are coupled with the Result - Traces/Labels configuration (refer to
Traces - SONET/SDH on page 244).
Format: Allows the selection of the expected format:
16 Bytes (default), or 64 Bytes.
Expected: Allows entering the expected J0 trace message for
TIM-S/RS-TIM, and J1 for TIM-P/HP-TIM. See Default values/messages
on page 162.
TCM Access Point Identifier
Note: Available when TCM is enabled from the Signal - Signal Configuration
STS/AU/TU Path (N1)
Enter the N1 value/message to be generated.
TC-TIM-P/HPTC-TIM: Enables the corresponding TCM Access Point
Identifier for the expected message defined. These settings are
coupled with the Traces configuration from Traces (SONET/SDH) on
page 162.
Copy RX allows to use the received TIM message as the expected one.