Test Setup - Test Configurator, Timer, and System

Packet Blazer

129

Services - Profile

The following table lists each component that may affect the minimum
frame size value.

Note: Sending traffic with frame size > 1518 in switched network may results in

losing theses frames.

EMIX button is available when EMIX type is selected. The EMIX frame
sequence is repeated until the test ends.

Quantity allows to select from 2 to 8 frames size values (default is 5).

EMIX Frame Sizes allows to set the EMIX frame sizes (default are 64,
128, 512, 1024, and 1518). The minimum frame size value is adjusted
according to the frame structure and components selected as shown
in the above table.

Restore Default button reverts the quantity and EMIX frame sizes to
their default values.

Component

Description

VLAN

4 bytes per VLAN (up to 2 VLAN)

UDP

8 bytes

Ethernet Header

14 bytes

IPv4

20 bytes

IPv6

40 bytes