beautypg.com

EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual

Page 215

background image

Test Results

Packet Blazer

205

Alarms/Errors

Period

For GFP layer, allows to set the alarm period associated with the client
management frames: 10 ms to 1200 ms (default is 100 ms).

User-Defined UPI available with GFP layer, allows entering the Client
Management Frame UPI value when GFP-User-Defined CMF alarm is
selected.

Inject button

For Manual mode: Manually generates the selected errors according to
the defect and the amount selected.

For Rate and Max Rate: Generates respectively the selected error at
the rate specified or at its theoretical maximum rate.

Note: The selected alarm/error as well as its injection mode and status are

displayed next to the Inject button.

The open/close pop-up button allows to respectively expand (up
arrow) or collapse (down arrow) a pop-up allowing to set the
alarm/error injection parameters.

UPI

Description for PTI = 100

0000 0000 and 1111 1111

Reserved

0000 0001

Client Signal Fail (Loss of Client Signal)

0000 0010

Client Signal Fail (Loss of Client Character
Synchronization)

0000 0011 through 1111 1110 Reserved for future use