Signal - signal configuration (otn) – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 148
Test Setup - Test Configurator, Timer, and System
138
FTB/IQS-85100G
Signal - Signal Configuration (OTN)
Signal - Signal Configuration (OTN)
Note: The following signal configuration parameters are available from the
interface block.
From the Test menu, tap Setup, Test Configurator, the interface block,
and on the Signal tab.
OTU4, OTU3, OTU3e1, or OTU3e2
FEC check box, when selected (default), enables the FEC in TX/RX
and allows to detect, report, and correct up to 8 symbol errors
(Correctable) per codeword. If there are over 8 symbol errors
detected, they are reported as uncorrectable errors.
Note: The FEC check box should be selected when the Scrambler check box is not
selected in order to prevent potential alarms caused by a lack of bit
transition on the optical signal. To disable FEC, first select the Scrambler
check box then clear the FEC check box.
Scrambler check box, when selected (default), provides enough
“0” and “1” transitions on the optical signal for clock recovery.
Note: The Scrambler check box should be selected when the FEC check box is not
selected in order to prevent potential alarms caused by a lack of bit
transition on the optical signal. To disable Scrambler, first select the FEC
check box then clear the Scrambler check box.