beautypg.com

Options menu, Firmware update – Haltech E8 User Manual

Page 49

background image

Haltech E11/E8 Instruction Manual

Options Menu
Firmware Update

This option should not be used unless you are instructed to update your firmware to fix a problem, or you
have purchased an upgrade that required firmware to be updated. Under no circumstances should
firmware be updated to a more recent firmware just for the sake of using the latest firmware.

Updating your ECU’s firmware

Turn on your ECU, but do not start your engine. Start your laptop with Halwin software and go online.
Check your firmware version and note the version information.

Figure 42 - Firmware Version Information

Before going any further, save the map that is currently in the ECU, this map will later be re-loaded into
the ECU after the update is complete.

Select the Firmware Update option. After you have selected the Firmware Update option, you will be
presented with the following dialog window:

Figure 43 - Firmware Update

Click on the button to the right of the filename to select the binary firmware file (this file will have a .bin file
extension) that you will use to update your ECU.

Make sure that your engine is not running. After the correct file appears in the ‘Firmware File’ field, press
the Next button. The ECU will reboot before Halwin begins to write to the ECU. As the firmware is being
written, a status message will inform you of what percentage of firmware writing is complete.

Copyright © Haltech 2008

Page: 49

Warning:

Before updating firmware, ensure that the ECU is turned on, but

the engine is not running. The outputs from the ECU should change to a

non-connected safe state , however, it is good practice to unplug the 34

pin connector on your ECU before beginning a firmware update operation.

This manual is related to the following products: