beautypg.com

Haltech E8 User Manual

Page 142

background image

Haltech E11/E8 Instruction Manual

Figure 146 - Channels to be Logged

Data Logging Rate

To select the Data logging rate, the user can click on the desired rate in the Data Logging Rate Options
Group Box. See Figure 146. The user has the option of selecting either 1 sample/sec, 10 samples per sec
or 200 samples/sec.

The available logging time is dependent on the rate that you log at, as well as the number of channels that
will be logged. The following table shows some typical logging times.

Number of Channels

Sample Rate

Logging Time (for a single pass)

10

1 sample / second

4.9 hours

10

10 samples / second (100ms)

29 mins 24 seconds

10

200 samples / second (5ms)

1 min 28 seconds

4

200 samples / second (5ms)

2 mins 43 seconds

For Advanced Users

:

Each sample has a 6-byte overhead and each channel uses 2-bytes to store its data. Data storage time
can be calculated using 448kB as the storage size.

Logging Options

The Logging Options group allows the user to select whether the Data logging will be enabled, and

Page: 142