Haltech E11/E8 Instruction Manual

Note the rate of change of throttle position is how far the throttle moves over a 10ms time frame. A fast
throttle movement could have a TPS rate of change of 15% this means that in a time frame of 10ms the
throttle position moved 15%. A slow throttle movement could have a TPS rate of change of 1%, which
means that in a time frame of 10ms the throttle position only moved 1%.

Figure 37 – Throttle Pump Setup Screen

Throttle Pump Settings:

Max Asynchronous Pulses

This is the maximum number of extra injector pulses that can happen

per injector output during an enrichment event.

Range: 0 – 10 pulses.

Default: 5.

Throttle Deadband

A rate of change of throttle position greater than this value will trigger an

enrichment event.

Range:

0.0 – 10.0 %.

Default:

0.5 %.

Delay Between Enrich Events

The minimum time between asynchronous enrichment

events. This is to stop excess fuelling when constantly pumping the throttle.

Range:

0.00 – 2.00 sec.

Default:

0.80 sec.