Road speed Threshold - The anti-lag can only activate below this road speed.
Max Throttle Position - The throttle position must be greater than this value for the anti-lag to turn on.
Enable On/Off Switch - This is a second digital input that can be enabled that acts as an override switch
can be added to disable the launch application of the anti-lag system.
Rev Limit Select - Can select between a fuel or ignition soft cut for limiting the RPM during anti-lag.
Anti-Lag becomes operational when the TPS, RPM and Coolant Temp requirements are met. If you have
enabled the “Use Aux In” parameter, then anti-lag will only operate an input is correctly configured for anti-
lag enable, and the input is in the active state.