7 example of printing from the setup software – KEYENCE BL-700 Series User Manual
Page 95

81
Chapter 4 Installing the Setup Software
4
4.7
Example of printing from the setup software
When “Print” is executed from the setup software, the following data is printed.
/ / / New setting data [Untitled] / / /
< < Model = BL-700 > >
[x] Selected
[_] -----------
=> Changed
1) Main
[Read mode]
[x] Single
[_] Multi 1 [_] Multi 2
[_]
Multi 3
[Data-send]
[x] After read
[_] At trigger input
[Repeat-reading time]
[10] x 100 ms
[Decoding match count]
[2] times
[Read error]
ERROR [4552524F52]
[Add Decoding match count]
[_] Enable
[Add scan count]
[_] Enable
[Add code type]
[_] Enable
[Add label orientation]
[_] Enable
2)
Trigger setup
[Signal type]
[x] Level
[_] One shot
[One shot input time]
[10] x 100 ms
[Input time]
[x] 2 ms
[_] 10 ms
[State]
[x] Nomally open
[_]
Nomally close
[Command for Trigger ON]
LON [4C4F4E]
[Command for Trigger OFF]
LOFF [4C4F4646]
[Test mode initiated with input ON]
[x] OFF
[_] Reading-rate check
[_] Tact check
[Test mode initiated upon power-up]
[x] OFF
[_]
Reading-rate check [_] Tact check
3) Comm Settings–1
[Baud rate]
9600 bps.
[Data bits]
[x] 7 bits
[_]
8 bits
[Parity]
[x]
Even
[_] Odd
[_] None
[Stop bits]
[x] 1 bit
[_] 2 bits
[RTS/CTS]
[_] Use RTS/CTS handshaking
[Multi-drop link(RS-485)]
[_] Enable
[ID number]
No. [1]
4) Comm Settings–2
[Use PLC]
[_] Enable
[Handshaking]
[x] None
[_] PASS/RTRY [_] ACK/NAK
[Header]
[x] None
[_] STX
[_] ESC [_] Custom
[Delimiter]
[x] CR
[_] CR + LF [_] ETX [_] Custom
[Partition mark]
: [3A]
[Intermediate delimiter]
, [2C]
[Checksum]
[_]
Enable
5) Utility
[Stability LED]
[_] Use stability LED
[OK/NG output duration]
[50] x 10 ms
[Preset data] = [no data]