Chapter 5 Serial Communication

90

5

Online test ON

Command: #TEST1
Response: OK

Online test OFF

Command: #QUIT
Response: OK

Online test check

Command: #TEST
Response: #TESTn

n = 0: Online test OFF
1: Online test ON

Command: BCLR
Response: OK

Command: SSET
Response: OK

Laser off

Command: LOCK
Response: OK

Resetting Laser off

Command: UNLOCK
Response: OK

When the Laser off command is executed, bar code read operation (laser
emission) is disabled until the Laser off command is reset by using UNLOCK
command.

The Laser off command is retained even after the power is turned off.

Command: RESET
Response: OK

Online test mode

Sets to online test mode (

➮ see P. 60).

Clearing transmission buffer

Clears data stored in the transmission buffer.

Shift to setting mode

Enters the setting mode (

➮ see P.4).

Laser off/Resetting Laser off

Turns off the laser emission when the laser beam may cause injury to an operator
(

➮ see P.2).

Reset

Resets the BL-700 software.