Chapter 5 Serial Communication

92

5

5.3.2 Details on Parameter Setting Commands

The following describes how to change the BL-700’s settings through command
communication.

You can use the setup software to change the BL-700’s settings instead of these
commands.

Communication Details

1. Send the direct control command SSET to the BL-700.

The BL-700 will shift to setting mode.
After successfully executing the command, the BL-700 sends back an OK.

2. After the BL-700 shifts to setting mode, send the command (setting change

command) corresponding to the item to be changed to the BL-700.
After successfully executing the command, the BL-700 sends back an OK.
If an error occurs with this command, the BL-700 sends back ERRnn. (nn
sttands for error code numbers.)

3. To confirm the current settings, send a setting confirmation command.

After successfully executing the command, the BL-700 sends back an OK.
If an error occurs with this command, the BL-700 sends back ERRnn.

4. To save the current settings in the EEP-ROM, send SAVE to the BL-700.

Once you save the settings in the EEP-ROM, the BL-700 will start with these
settings when the BL-700 is turned on next.
After successfully executing the command, the BL-700 sends back an OK.
If an error occurs with this command, the BL-700 sends back ERRnn.

5. To quit the setting mode and perform the normal bar code reading, send SEND

to the BL-700.
After successfully executing the command, the BL-700 sends back an OK.
If an error occurs with this command, the BL-700 sends back ERRnn.

Communication format

When the command format is [Command][CR], the response format is
[Response][CR]. When the command format is [STX][Command][ETX], the
response format is [STX][Response][ETX].

can be added at the end of the command being sent. In this case, however,
is not added to the response data.

When is added before the command being sent, characters in the BL-700’s
command receiving buffer are cleared.

If the BL-700’s command receiving buffer contains erroneous characters due to a data
transmission error during communication, add to the command being sent.

Note: For command communication, set the time duration between transmission of
each character (byte) to up to 30 seconds. If this duration exceeds 30 seconds, the
BL-700 cancels the received characters.

Command

Response

Command CR

Response CR

STX Command ETX

STX Response ETX