Appendix m default setting list, Appendices – KEYENCE BL-700 Series User Manual
Page 158
![background image](/manuals/658133/158/background.png)
Appendices
144
Appendices
Appendix M Default Setting List
■ Bar code setup
Parameter
Code 1
Code 2
Code 3
Code 4
Code type
CODE39
Coda bar
UPC/EAN
None
Maximum number of digits
32
32
–
Minimum number of digits
03
03
–
Send start/stop character
Don’t send
Send
–
Start/stop character type
Lowercase
–
Test check digit
Don’t test
Don’t test
–
Read JAN (More than
All EAN 13-digit,
one can be selected.)
EAN 8-digit
and UPC-E
are readable.
Number of output
13 digits
digits of UPC-A
Add “0” to UPC-E
Don’t add
system code
Set specified-digit
Don’t set
Don’t set
Don’t set
–
output function
Set label reading in
Don’t set
Don’t set
Don’t set
–
the specified direction
■ Main setup
Read mode
Single
Data send trigger
After reading
Decode match count
2
Data addition function
None
Reading error code
ERROR
■ Trigger input setup
Selection method
Level signal trigger
Input time
2 ms
Input polarity
Normal Open
Start test mode at trigger input ON
Don’t start
Start test mode at power ON
Don’t start
Trigger ON command
LON
Trigger OFF command
LOFF