4 brooktrout driver, 5 serial modem driver, 6 27951–28027: ipfax driver – FaxBack NET SatisFAXtion 8.6 - Manual User Manual
Page 183
4 – Appendices
NET SatisFAXtion 8.6 Manual
183
4.1.4
Brooktrout Driver
4.1.5
Serial Modem Driver
10785 Windows serial device name unknown:
Cannot access the
configured modem. Check that no other application is using the modem.
10786 The serial device is in use by another program:
Cannot access
the configured modem. Check that no other application is using the modem.
4.1.6
27951–28027: IPFax Driver
27951 Bad open ring 0 / kernel mode driver:
There is another instance
of the IPFax driver already loaded, or the Windows account attempting to load
the driver does not have Administrative permissions.
27969 Send collided with receive:
An outbound port was allocated just
as the port began to receive a call. Error type:
BUSY
.
27975 WsaSendTo error:
The gateway address is not a valid IP address.
Error type:
NON_RETRYABLE
.
27976
SIP Invite sent 7 times with no response: The gateway did not
respond to SIP Invite requests. Check the configured gateway IP address, and
any firewall in between. Error type:
RETRYABLE
.
27977 Timeout waiting for invite final response:
Call was not
answered in the configured time period. Error type:
NO_ANSWER
.
27978 Unknown
SIP response code: Received nonstandard SIP code
from media gateway. See extended error code. Error type:
RETRYABLE
.
27979 Timeout waiting for reinvite to fax:
The call connected, but the
gateway failed to send a reinvite for T.38 either because there were no fax tones
detected on the remote side or because the gateway does not support T.38.
Error type:
RETRYABLE
.
27980 Timeout waiting for ACK of OK for reinvite to fax:
Media
gateway incompatibility or severe network issues. Error type:
RETRYABLE
.
27981
SIP response sent 7 times with no ACK: Media gateway
incompatibility or severe network issues. Error type:
RETRYABLE
.
27982 Reinvite OK received without
T.38 media: Media gateway
incompatibility. Error type:
RETRYABLE
.
27983
SIP bye received before fax was completed: The remote fax
device hung up before the fax was completed. The gateway also did not include
a Q.850 cause code for this disconnect, otherwise this would likely be 0x7210
Normal Call Clearing instead. Error type:
RETRYABLE
.
27984 Unable to open even
RTP por t followed by consecutive RTCP
por t. Error type:
NON_RETRYABLE
.
27985 No Answer, remote device did not respond to handshake:
The call connected and T.38 communication was established, but the remote
device failed to respond to repeated attempts to handshake. This commonly
occurs when using T38_INVITE to initiate T.38 media without the initial RTP
audio phase. The timer is 35 seconds. Error type:
RETRYABLE
.