1118 Wrong response after training:

After sending 1.5 seconds of

training data, the remote unit should have sent a CFR or FTT frame. It sent
something else. Error type:

RETRYABLE

.

1119 No FTT or CFR received after 3 DCS/training sequences:

The

call connected and fax communication was established. The receiving and
sending devices exchanged CSI/DIS and TSI/DCS/training signals. After that,
the receive side is expected to send a CFR (confirmation) or FTT (failure to train),
it did neither. Handshaking was attempted and failed twice more, at which point
IPFax terminated the call. Error type:

RETRYABLE

.

1120 No response after sending 3 end of page commands:

After

reaching the end of the page, an end-of-page command (MPS) is sent and an
acknowledgment (MCF) is expected from the remote device. The MCF was not
received. The MPS was attempted twice more. After the third failure to respond,
the call was terminated. This can be caused by the remote device hanging up,
line impairment such that the modem could not detect and encode the MCF
command, or line noise such that our MPS was not detected by the remote
device. Error type:

RETRYABLE

.

1121 Invalid response after end-of-page:

After sending the end of page

command to the remote, the remote should have sent a MCF, PIP, RTP, PIN, or
RTN response. It sent something else. Error type:

RETRYABLE

.

1122 Receiver sent DCN:

Normally, the receiver should never send a DCN

disconnect signal. This could be due to line impairment causing a timeout on
the receive side, or a user manually pressing a cancel button on the receiving
fax machine. Error type:

RETRYABLE

.

1123 Modem does not suppor t any of the configured receive baud

rates: The driver has been setup to allow only a certain number of allowed
send baud rates, but the modem does not support any of them. An example
would be where a user does not want to send a fax slower than 12000 baud,
but the modem only supports 9600 baud as its highest baud rate. Error type:

NON_RETRYABLE

.

1123 Modem does not suppor t any of the configured send baud

rates: The driver has been setup to allow only a certain number of allowed
send baud rates, but the modem does not support any of them. An example
would be where a user does not want to send a fax slower than 12000 baud,
but the modem only supports 9600 baud as its highest baud rate. Error type:

NON_RETRYABLE

.

1127 Remote device does not suppor t fax:

The remote modem

indicated it is not capable of faxing. Error type:

NON_RETRYABLE

.

1128 Invalid response to

ECM block: The valid responses from the

remote following the transmission of an ECM block should be RNR, PPR or MCF.
Some other signal was received. Error type:

RETRYABLE

.

1129 Remote fax not ready for next page:

The T5 timeout (60 seconds

± 5 seconds) occurred while exchanging RR and RNR signals for an ECM send.
Error type:

RETRYABLE

.

1130 No response to

ECM end-of-page: The sender had received a RNR

at which time it responds with an RR signal. It then expects the remote to send
either a RNR or an MCF within T4 seconds. There was no response received.
Error type: