beautypg.com

4 add new dll to the server load list, 11 scanner / mfp, Scanner / mfp – FaxBack NET SatisFAXtion 8.6 - Manual User Manual

Page 141

background image

2 – Server Administration

NET SatisFAXtion 8.6 Manual

141

PacketPath

[string]: Set to the Order Packet Folder to use with this

instance of the Connector API module.

RegisteredName

[string]: Set to the account name you created on the

fax server in the previous step.

RegisteredPassword

[string]: Set if a password was set on the

account, otherwise create the string value but leave blank.

ScanRate

[dword]: Milliseconds to wait between checking for new

packets.

Suppress_Header

[dword]: 1 – suppress header. 0 – do not suppress

header.

2.10.3.4

Add New DLL to the Server Load List

In order for the server to load the new instance of the Connector API module it
must be added to the registry under

HKLM\Software\FaxBack\WLoader\LOAD6

.

The name is a text description of the module, and the value is the DLL to load
followed by the name of the registry key to use. For example:

[HKEY_LOCAL_MACHINE\SOFTWARE\FaxBack\WLoader\LOAD6]

"Clarity Compatibility Server 2"="ASC2CAS_2.dll ASCIIPacketServer_2"
"Clarity Compatibility Server 3"="ASC2CAS_3.dll ASCIIPacketServer_3"

"Clarity Compatibility Server 4"="ASC2CAS_4.dll ASCIIPacketServer_4"
"Clarity Compatibility Server 5"="ASC2CAS_5.dll ASCIIPacketServer_5"

2.11

Scanner / MFP

NET SatisFAXtion has integrated support for Hewlett-Packard Digital Sender and
some Xerox WorkCenter Pro and Xerox Document Center multi-function devices.
Other multi-function devices can be integrated typically by configuring them to
send email to the fax server and using the SMTP or POP3 Email Gateway.

HP and Xerox MFPs can be configured using the Change Server Settings utility,
Start ► Programs ► NET SatisFAXtion ►

Change Server Settings. Change

to the Scanner/MFP tab. Note that both Hewlett-Packard and Xerox MFPs
require their own driver software, which must be installed and configured before
configuring NET SatisFAXtion. Refer to manufacturer-provided documentation for
installation and configuration.