Compressed air, Computer specifications, Drill and drill bit requirements – Dynojet 424x: Installation Guide User Manual
Page 18: Electrical requirements, Environmental requirements

In Ground Model 424x/424xLC
2
Automotive Dynamometer Installation Guide
C H A P T E R 1
Dynamometer Specifications and Requirements
1-8
C
OMPRESSED
A
IR
The following requirements are needed for the air brake:
• Clean and dry air, between 100-140 psi
• shut off valve
• 1/4-inch NPT pipe thread connector (to attach air to the dyno), if air hose does not
have a 3/8-inch inside diameter
• have a 3/8-inch inside diameter
C
OMPUTER
S
PECIFICATIONS
You will need to provide a computer system to run the WinPEP software. A complete
list of system requirements can be found in your WinPEP 7 User Guide. This manual is
included with your dyno and is also available on your WinPEP 7 CD.
D
RILL
AND
D
RILL
B
IT
R
EQUIREMENTS
You will need to provide a drill and drill bit capable of drilling holes in concrete. Refer
to Appendix A for more information on installing Red Head Anchors.
• drill bit size: 1/2-inch
• minimum hole depth: 1 5/8-inch (41.2 mm)
E
LECTRICAL
R
EQUIREMENTS
E
NVIRONMENTAL
R
EQUIREMENTS
description
specifications
Power Requirements: 4WD electronics
110v 60Hz or 240v 50Hz
Power Requirements: dyno electronics
110v 60Hz or 240v 50Hz
Power Requirements: hydraulic motor
110v 60Hz or 240v 50Hz or 60Hz
Power Requirements: computer
110v 60Hz or 240v 50Hz
Power Requirements: optional eddy
current brake
240v 30amp single phase circuit for each eddy current
brake
Refer to Appendix B for more information.
description
specifications
Temperature
operating min./max
10°C/50°C (50°F/122°F)
storage min./max
0°C/70°C (32°F/158°F)
Humidity
0 to 95% non condensing