ADS Environmental Services IETG FlowHawk QR 775012 A4 User Manual
Page 88
Sensor Installation and Connection 3-29
with the depth crystals facing downward toward the inside
of the ring (flow surface).
SURFACE COMBO SENSOR
SENSOR MOUNTING PLATE
Mounting the Surface Combo Sensor to the mounting plate on the ring
Note: The new version of the Surface Combo Sensor
(p/n 8K-CS5-V2-XX-30) referenced here and throughout
this manual is undergoing final testing and evaluation.
Contact the IETG Service Centre for sensor availability.
This new version includes a different mounting plate and
involves a slightly different installation procedure, as
described in this manual, than the existing Surface Combo
Sensor (p/n 8K-CS3-V2-XX-30). To install the existing
version of the sensor onto the mounting plate, refer to the
instructions below for the Ultrasonic Depth Sensor.
Ultrasonic Depth Sensor Mount this sensor by sliding
the sensor into the grooves on the sensor mounting plate
(at the top of the ring) from the upstream end until the
sensor contacts the backstop. The sensor cable should exit
the downstream edge of the ring. Orient the sensor with
the four transducers facing downward toward the inside of
the ring (flow surface).