Specifications

A-7

Surface Velocity

Accuracy

+/- 0.08 meters per second (0.25 ft/sec) or 5% of
the actual reading (whichever is greater) in flow
velocities from 0.30 to 4.57 m/s (1.00 to 15.00
ft/sec)

Note: Flow conditions may cause the designated
accuracy to vary and hinder or prevent the
effective use of surface velocity technology.

Deadband

76 mm (3 in) from the bottom of the rear,
descended portion of the sensor

Minimum

Velocity

0.3 meters per second (1 ft/sec)

Frequency

Varies based on the parameter settings

Range

7 to 1067 millimeters (3 to 42 in)

Resolution

0.003 meters per second (0.01 ft/sec)

Surcharge Peak Velocity

Range

-9.1 to 9.1 meters per second (-30 to 30 ft/sec)

Frequency

250 kHz

Resolution

0.003 meters per second (0.01 ft/sec)

Accuracy

0.06 m/sec (+/- 0.2 ft/sec) or 4% of actual peak
velocity (whichever is greater) in flow velocities
from -1.52 to 6.10 m/sec (-5 to 20 ft/sec)