Keypad input – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 78
![background image](/manuals/580383/78/background.png)
78
Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
Chapter 5 Configure and Start Up the Kinetix 350 Drive System
Keypad Input
The Kinetix 350 drive is equipped with a diagnostic status indicator and three
push buttons that are used to select displayed information and to edit a limited
set of parameter values. Parameters can be scrolled by using
. To view a
value, press
. To return back to Scroll mode press
.
After pressing
on editable parameters, the yellow status indicator D blinks
indicating that the parameter value can be changed. Use
to change the
value. Press
to store the new setting and return back to Scroll mode.
Table 34 - Status Display Information
Status Indicator
Description
Hx.xx
Hardware revision. For example, H2.00.
Fx.xx
Firmware revision. For example, F2.06.
dHCP
Ethernet DHCP Configuration: 0=’dHCP’ is disabled; 1=’dHCP’ is enabled.
IP_1
Lets you modify the first octet of the IP address.
IP_2
Lets you modify the second octet of the IP address.
IP_3
Lets you modify the third octet of the IP address.
IP_4
Lets you modify the fourth octet of the IP address.
nEt1
Lets you modify the first octet of the netmask.
nEt2
Lets you modify the second octet of the netmask.
nEt3
Lets you modify the third octet of the netmask.
nEt4
Lets you modify the fourth octet of the netmask.
gat1
Lets you modify the first octet of the gateway.
gat2
Lets you modify the second octet of the gateway.
gat3
Lets you modify the third octet of the gateway.
gat4
Lets you modify the fourth octet of the gateway.